Test and Qualification
A system is designed against published methods and then measured against them: temperature and humidity in our own chambers, dimensions on the coordinate measuring machine, and only what the chambers cannot reproduce at an external laboratory.
- MIL-STD-810G, MIL-STD-461E and MIL-DTL-38999
- Hot / cold and humidity chambers on site
- Dimensional inspection on a 5-axis CMM
- External laboratory for the remaining conditions

Where this work happens
Production, Integration, Test and Qualification Centre
Ahi Evran St. 134, 06374 Yenimahalle, Ankara
Machining, coating, cabling, assembly, dimensional inspection and environmental testing. A part is cut, measured and tested in the same building, so a dimensional or environmental problem is found here rather than at the customer.

Qualification
Designed against published methods
Systems are designed to MIL-STD-810G environmental conditions, MIL-STD-461E for electromagnetic compatibility and MIL-DTL-38999 for electrical connections. Temperature and humidity testing is done in our own chambers; the table below lists the methods a system is designed against.
- EnvironmentalMIL-STD-810G
- EMI/EMCMIL-STD-461E
- Electrical connectionsMIL-DTL-38999
| Condition | Method |
|---|---|
| Operating temperature | Method 501.5 Proc. II +60 °C (+85 °C optional) · Method 502.5 Proc. II −22 °C (−30 °C optional) |
| Storage temperature | Method 501.5 Proc. I +70 °C · Method 502.5 Proc. I −32 °C |
| Solar load | Method 501.5 Proc. II, operating, +55 °C |
| Vibration | Method 514.6 Proc. I, Category 4, Figure 514.6C-1 |
| Rain | Method 506.5 Proc. I |