Test and Qualification
A system is designed against published methods and then measured against them: temperature and humidity in our own chambers, dimensions on the coordinate measuring machine, and only what the chambers cannot reproduce at an external laboratory.
- MIL-STD-810G, MIL-STD-461G and MIL-DTL-38999
- Hot / cold and humidity chambers on site
- Dimensional inspection on a 5-axis CMM
- External laboratory for the remaining conditions

Qualification
Designed against published methods
Systems are designed to MIL-STD-810G environmental conditions, MIL-STD-461G for electromagnetic compatibility and MIL-DTL-38999 for electrical connections. Temperature and humidity testing is done in our own chambers; the table below lists the methods a system is designed against.
- EnvironmentalMIL-STD-810G
- EMI/EMCMIL-STD-461G
- Electrical connectionsMIL-DTL-38999
| Condition | Method |
|---|---|
| Operating temperature | Method 501.5 Proc. II +60 °C (+85 °C optional) · Method 502.5 Proc. II −22 °C (−30 °C optional) |
| Storage temperature | Method 501.5 Proc. I +70 °C · Method 502.5 Proc. I −32 °C |
| Solar load | Method 501.5 Proc. II, operating, +55 °C |
| Vibration | Method 514.6 Proc. I, Category 4, Figure 514.6C-1 |
| Rain | Method 506.5 Proc. I |